Kia Rio: Ambient Temperature Sensor / Cluster Ionizer (FATC only)

Kia Rio 2017-2025 YB Service Manual / Heating,Ventilation, Air Conditioning / Ambient Temperature Sensor / Cluster Ionizer (FATC only)

Description and operation
Description

The cluster ionizer helps to clean up odors in the vehicle or from the air-conditioner system.

When the ignition switch ON, the inoizer runs a "CLEAN" mode and then a "ION" mode, switching every about 15 minutes.

In the “CLEAN” mode, the cluster ionizer generates negative and positive ions to help clean smells from the air

In the "ION" mode, the cluster generates negative ions and cleans inside air of a vehicle.

Repair procedures
Inspection
1.

Press the MODE switch more then 4 times within 2 seconds while pressing the OFF switch.

Display
Fail description
00
Normal
50
Cluster ion generator fault

* For diagnostic procedure, refer to DTC guide.

Replacement
1.

Disconnect the negative (-) battery terminal.

2.

Remove the front bumper.

(Refer to Body - "Front Bumper Assembly")

3.

Disconnect the connector (A) and then remove the cluster ionizer (B) after loosening the mounting screws.

4.

Installation is the reverse order of removal.

Auto Defogging Sensor (FATC only)
Description and operation Description The Auto Defogging Sensor is installed on front windshild glass. The Auto Defogging Sensor senses moisture on the windshild. The air conditioner c ...

Heater
...

Other information:

Kia Rio 2017-2025 YB Service Manual: Clutch & Brake


Description and operation Description Brakes The automatic transaxle (A4CF1) uses the low and reverse brake and the second brake. The low and reverse brake is fixed by the low and reverse annulus gear and overdrive planetary carrier. The overdrive sun gear is held on the transax ...

Kia Rio 2017-2025 YB Service Manual: Temperature Control Actuator


Description and operation Description The heater unit includes mode control actuator and temperature control actuator. The temperature control actuator is located at the heater unit. It regulates the temperature by the procedure as follows. Signal from control unit adjusts positio ...